Insulation, vapour-barrier work and thermal-envelope repairs for coolers, freezers and temperature-controlled rooms.
What the building is telling you
Signs you may need this
These show up in operation long before they show up in a report. The cause is usually in the assembly, not in how the space is being used.
- A cooler or freezer that struggles to hold its set point
- Frost building up on panels, ceilings or door frames
- Condensation on the outside face of a cold-room wall
- Refrigeration running far longer than it used to
- Damaged or delaminated panels at corners and door openings
- Ice on the floor at the threshold
In a cold room, the vapour barrier does the hard work
A cold room fails at its weak points long before its average performance drops: a damaged panel joint, a door seal, a penetration for piping. Warm humid air that reaches a cold surface condenses and then freezes, so frost is not a cosmetic issue, it is a map of where the envelope is broken. The vapour control layer sits on the warm side, and its continuity matters as much as the thickness of the insulation itself.
Is this the right scope for your building?
When it applies
- Frost or condensation is appearing on the envelope
- Panels, joints or door surrounds are damaged
- Refrigeration is compensating for an envelope problem
When something else comes first
- The refrigeration equipment itself is failing, which is a mechanical scope
- A control or defrost setting is the cause, which is worth checking before any construction
Envelope work will not compensate for undersized or failing refrigeration. If the assessment points to the equipment, we say so, because insulating around a mechanical problem only delays it.
How the work runs
Our process
Inspection of the envelope
Panels, joints, door surrounds, penetrations and where frost is forming.
Locating the vapour path
Where humid air is reaching a cold surface, which is what the frost is showing.
Planning around the product
Sequencing so the contents can be moved or protected during the work.
Repair and insulation
Damaged sections corrected and continuity of the vapour layer restored.
Verification
Envelope checked with the room back at temperature.
About this service
Questions we get on this one.
Specific to cold room insulation & repair. Tap a question.
Eco-Therma
Usually replies the same day
Can the room stay in service during the work?
Sometimes in phases, sometimes not. It depends on the temperature you have to hold and on how much of the envelope is open at once — we tell you plainly which one applies.
Why does the vapour barrier matter more in a cold room?
The moisture drive is constant and runs one way, from the warm humid side toward the cold one. A gap in the barrier does not just lose energy, it puts water inside the assembly.
What causes frost on a cold-room ceiling?
Warm humid air reaching a cold surface, usually through a break in the envelope or a poorly sealed penetration. Finding that break is the first part of the job.
A practical next step
Request a review on cold room insulation & repair.
Send the project details, the scope and any drawings or specifications you already have. We review them before quoting and come back with what still needs to be confirmed.